Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-QT3S
Brand:fengtu
1.Nitrogen Dioxide Detector Technical Parameters
Nitrogen Dioxide Detector used to monitor the concentration of nitrogen dioxide in general industrial environment, easy to use, cost-effective.
| model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
| QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
| QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
| QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
| QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. Nitrogen Dioxide Detector Product Dimensions

Air quality sensors are used to detect airborne pollutants such as the familiar PM10 and PM2.5 particulate matter. These particles can affect our health, especially PM2.5 because it is very fine and can penetrate deep into the lungs. The Air Quality Index (AQI) uses the concentration of these partic...
Soil Moisture Testing Equipment is a research result obtained through scientific methods and multiple equipment experiments. It can continuously observe and conduct in-depth analysis of the relevant conditions of the soil.Soil Moisture Testing Equipment is divided into two parts: hardware and softwa...
The river water level and rainfall monitoring system is based on the Internet of Things technology, combined with meteorological data and other relevant parameters to achieve real-time observation and management of river flow. It is mainly used in flood control, flood prevention early warning and wa...
Environmental Sensors integrates six monitoring functions—temperature, humidity, illumination, PM2.5, PM10, and noise—delivering measurement accuracies of ±0.3°C for temperature, ±3% RH for humidity, and ±1.5 dB for noise. Data for all parameters is output simultaneously via an RS485 int...