1. O3 gas sensor technical parameters
O3 gas sensor monitors ozone concentrations in industrial environments in real time, ensuring operator safety and preventing equipment damage.
model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. O3 gas sensor product dimensions
chlorophyll sensor detected the fluorescence of chlorophyll and estimated the concentration of phytoplankton, which provides a high-performance measurement of chlorophyll A....
Water quality monitoring stations need to obtain real - time data of various water quality parameters, such as pH value, dissolved oxygen, chemical oxygen demand (COD), ammonia nitrogen, etc. Water quality sensors are devices specifically designed to measure these parameters. They can convert the ph...
soil sensors are used to monitor soil moisture conditions. They provide information on soil moisture, salinity, temperature, etc. They are suitable for horticulture, agriculture, indoor and outdoor plants....
Automatic radar water level rainfall monitoring system has the advantages of simple structure and low cost, which is widely used in water conservancy projects. At present, the number of automatic radar water level rainfall stations is increasing and the degree of automation is improving, and there h...