Model:FT-QT2S
Brand:fengtu
1. Technical parameters of SO2 sensor
SO2 sensor continuously monitors the concentration of the sulfur dioxide sensor and transmits the data to the monitoring system.
| model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
| QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
| QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
| QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
| QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. SO2 sensor product dimensions

Duct air velocity measurement is a common operation in industrial production and environmental monitoring. Its main purpose is to monitor the flow rate of wind velocity inside a pipeline to ensure that the fluid (usually gas) inside the pipeline is within a controlled range.In industrial production,...
The River Level Monitoring Station, as a key product of the Intelligent River Monitoring Project, plays an extremely important role in the field of hydrological monitoring.The flow velocity monitoring makes use of the Doppler effect of radar waves. When radar waves are emitted to the water flow, the...
In the field of soil and water conservation research, runoff plots are important observation units. They refer to enclosed observation areas with a certain area and boundaries demarcated on sloping or flat land for studying the laws of soil erosion. These areas, equipped with enclosing ridges, catch...
Air quality has a far-reaching impact on human health and the ecological environment. Along with the rapid progress of industrialisation and urbanisation, the problem of air pollution has become increasingly serious. This situation not only poses a threat to people's health, but also has a serio...