Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-P496
Brand:fengtu
1、Fluorescence Quantitative PCR Detection System Product Overview
Fluorescence Quantitative PCR Detection System can be flexibly placed in scenarios that require space, such as biosafety cabinets, quick detection boxes, mobile laboratories, and laboratory countertops.The Fluorescence Quantitative PCR Detection System is a four-channel, 96-well fluorescence quantitative PCR instrument that combines high performance, intelligence, and exceptional reliability. It integrates a precise optical detection system, efficient and stable temperature control technology, and a highly flexible and convenient user experience. It is dedicated to providing a fast, accurate, and reliable integrated solution for molecular diagnostics, life science research, pathogen detection, and gene expression analysis.
The core advantage of the Fluorescence Quantitative PCR Detection System lies in its "dual-mode intelligent control": it can operate independently for rapid on-site testing and efficient daily operations, or connect to computer software for complex program design, high-throughput data processing, and in-depth analysis. Furthermore, a series of intelligent and user-friendly designs make experiment initiation simpler, the process more stable, and data management more efficient.
2、Fluorescence Quantitative PCR Detection System Product Advantages
1. Intelligent Operating System, Complete Control Over Experiments
A. Flexible Dual-Mode Control: Supports independent operation via the instrument's touchscreen and remote control and data management via computer software, adapting to different experimental scenarios.
B. Program Updates and Presets: Supports online updates of experimental programs and includes a wealth of built-in preset experimental program templates. Users can also customize and save frequently used templates for quick one-click startup, significantly improving operational efficiency.
C. Simplified Startup Experience (Optional): A customizable integrated camera scanning system allows users to automatically identify and load the corresponding experimental program by simply scanning the QR code on the sample plate or program card, simplifying the process and avoiding human error.
D. Easy Operation: Both the touchscreen interface and computer software are designed to be intuitive and easy to understand, allowing new users to quickly get started. Pre-installed common program templates further simplify the operation process.
2. Precise and Stable Temperature Control and Optical Core
A. Long-Term Precise Temperature Control System: Uses imported high-quality TEC semiconductor cooling modules for precise temperature control (±0.1°C) and excellent temperature uniformity between wells (≤±0.3°C). The system boasts excellent stability, minimal performance degradation over long-term use, and a calibration cycle of several years, significantly reducing maintenance costs and operational downtime.
B. Maintenance-Free and Sensitive Optical System: Equipped with 4 independent LED light sources and 4 independent photodiode detectors, enabling simultaneous and precise detection of four fluorescence channels. Uses ultra-long-life imported light sources, requiring no maintenance, calibration, or replacement during its design lifespan, ensuring long-term consistency and high sensitivity of detection results.
C. Excellent Data Quality: High experimental linearity (R²≥0.999) and excellent repeatability (low CV value between wells) ensure accurate and reliable quantitative results and high data confidence.
3. Efficient and Convenient Data and Output Management
A. Multiple Data Export Methods: Supports direct copying via USB storage devices or data transfer to local servers or the cloud via Wi-Fi wireless network, providing convenience and flexibility to meet various laboratory data management habits.
B. Rich Report Export and Printing: Supports generating and exporting experimental reports in various formats (such as PDF and Excel). The instrument is compatible with USB thermal printers, Bluetooth wireless printers, and standard A4 printers, allowing for one-click export and printing of professional reports directly from the instrument or via a computer, facilitating result archiving and instant sharing. 4. Fast, Efficient, and Durable
A. Rapid Heating and Cooling: The optimized temperature control system features high-speed heating and cooling capabilities, significantly shortening single-cycle and overall testing times, and increasing experimental throughput.
B. Extended Service Life: All core components are made of industrial-grade durable materials and designed for long-term reliability, ensuring a lasting return on investment for users.
3、Fluorescence Quantitative PCR Detection System Application Scenarios:
Basic scientific research, pathogen detection, meat product adulteration detection, genetically modified organism (GMO) detection, food safety testing, drug development and rational drug use, gene expression, water monitoring, pine wood nematode detection, pet testing, and livestock disease detection.
4、Fluorescence Quantitative PCR Detection System Technical Specifications
1. Features a high-grade aluminum alloy sample holder with excellent thermal conductivity, corrosion resistance, and oxidation resistance, along with Peltier heating and temperature control, and a comprehensive sealing design. Neither sample solution nor condensation will leak into the Peltier temperature control element or other electronic components below the sample holder, effectively extending the instrument's lifespan.
2. Utilizes a high-precision PT1000 temperature sensor, achieving a temperature control accuracy of 0.01℃, ensuring accurate temperature control.
3. Sample throughput: 96 × 0.2ml PCR full plate (skirtless, semi-skirted), 0.2ml single tube, 0.2ml 8-tube strip.
4. Open reagent and consumables system: Compatible with reagents from any brand, suitable for standard 96-well plates, 8-tube strips, or 0.2ml PCR single tubes.
5. Employs four high-intensity, broad-spectrum, long-life LED solid-state light sources (blue, green, red, and yellow) to ensure strong light intensity across the entire spectral detection range, improving detection sensitivity. These LEDs generate no heat, have a long lifespan, and are maintenance-free for life.
6. High-sensitivity detector: Uses a high-sensitivity photomultiplier tube imported from Japan for higher detection sensitivity.
7. No optical path correction required: The scanning system ensures that the signal excitation and detection optical paths are completely consistent for each well, eliminating the need for optical path correction and thus freeing up a correction channel, enabling true four-channel gene detection. ★
8. Number of channels: 4 channels.
9. Channel crosstalk: High-precision narrow-band filters are used to greatly reduce channel crosstalk, and the software can also correct crosstalk parameters. 10. Detection Sensitivity: Capable of detecting single-copy DNA templates and clearly distinguishing between 1000 and 2000 copies of plasmid DNA.
11. Linear Detection Range: 10 orders of magnitude ★
12. Supports common fluorescent dyes and probe detection methods, such as SYBR Green I, Eva Green, Taqman, FRET, Molecular Beacons, Scorpions, Amplifluor, etc.
13. Module Temperature Range: 4-99℃
14. Control Mode: Built-in PCR operating system on the system screen or Windows computer ★
15. Interface: USB connection to computer
16. Operating Noise: Silent technology, maximum operating noise does not exceed 60dB during operation.
17. Operating and Analysis Software
17.1 Allows defining sample wells after running the program, saving experimental time.
17.2 Allows opening other experimental data results for viewing and analysis simultaneously while the program is running.
17.3 The software automatically calculates the baseline range and sets the threshold line, providing users with reliable and accurate data results.
17.4 Experimental program settings and detection results can be directly printed as an experimental report, supporting export in multiple file formats and data styles such as XLS, CSV, and WORD ★
17.5 Results from the same batch of experiments can be grouped for independent data analysis, with a maximum of 12 groups.
17.6 Provides both Chinese and English software interfaces. ★
17.7 The software can be installed on multiple computers without limitation, no purchase of usage rights is required, and lifetime free upgrades are available. ★
Fluorescence Quantitative PCR Detection System Instrument Technical Specifications
| Basic performance | |
| Dimensions | 318*425*217.5(mm) |
| Weight | 12.3Kg |
| Power supply | 220V |
| Power | Maximum working power 960w |
| Operating system | Comes with Android operating system |
| External computer | External Windows computer (Win7 system above) |
| System language | Real-time switching between Chinese and English |
| Communication interface | Square USB |
| Operating environment parameters | |
| Operating ambient temperature | 18~35℃ |
| Operating environment relative humidity | 0%~85% |
| Transport and storage temperature | -20~55℃ |
| Transport and storage relative humidity | 0%~85% |
| System performance | |
| Sample size | 96-well*0.2ml |
| Sample volume | 15~100ul |
| Applicable consumables | 0.2ml single tube, 8×0.2ml rack tube, 96-well plate |
| Temperature control range | 4~99℃ |
| Hot cover temperature | 30℃-108℃(default 105℃, hot plate temperature adjustable) |
| Temperature control method | High-performance imported semiconductors |
| Gradient temperature control | 6-module gradient temperature control, maximum temperature difference support 35℃ |
| Rise rate | 4.5℃/s(MAX) |
| Cooling rate | 3.4℃/s(MAX) |
| Temperature control accuracy | ±0.1℃ |
| Temperature homogeneity | ±0.25℃ |
| Temperature accuracy | ±0.1℃ |
| Operation function | Pre-set projects and analysis parameters, easy to operate |
| Report | Support report custom modules, 96-well sub-project printing |
| Analytical function | With multiple qPCR data analysis functions, it can detect 4 detection channels simultaneously. |
| Power-off protection | One-click restart of interrupted experiments |
| Instrument information | Have fault records, analysis, prompt functions, more convenient remote problem solving. |
| Analysis algorithm | Amplification curve, standard curve quantitative, melting curve, gene typing (SNP), relative quantification |
| Support for HRM detection | Support |
| Data Export | The experimental results can be directly exported in the form of graphics and tables; the detailed content of the data report includes experimental conditions, data coordinates and tables, and data analysis parameters. |
| Data format | XLS, CSV, DOCX, PDF |
| TouchDown function | Support time and temperature increase and decrease mode |
| Fluorescence detection system performance | |
| Detection sensitivity | Detectable single copy genes |
| Dynamic range | 1~10^10 |
| Fluorescence repeatability | CV<1% (using a certain brand of reagents for a 96-well uniformity test, the Ct difference of 96 wells remained within 0.5, and the CV remained within 1%). |
| Correlation coefficient | 0.99~1 (three replicates for each concentration, the correlation coefficient of the standard curve >0.99, the amplification efficiency was maintained between 99%~101%) |
| Amplification efficiency | 99%~101% |
| Credibility | Distinguish between 1000 and 2000 copies concentration differences |
| Laser light source | High power LED (maintenance free, long life) |
| Detector | High sensitivity photoelectric sensor |
| Excite and detect the transmission medium | High temperature resistant professional optical fiber |
| Excitation wavelength | 460nm~480nm, 525nm~545nm, 575nm~595nm, 600nm~620nm |
| Detect light wavelength | 505nm~525nm; 555nm~575nm; 600nm~620nm; 660nm~680nm |
In the fields of water conservancy management and flood control and disaster reduction, water level monitoring is of great importance, and the Water Level Monitoring System achieves efficient and accurate monitoring of water levels.The Water Level Monitoring System is mainly composed of front-end mo...
Ultrasonic Wind Speed Direction Sensor is a wind - measuring instrument produced by Fengtu....
how does a rain gauge work? Placed in an open area, it is measured based on the height of the precipitation that has accumulated in the container at a given time, and the change in rainfall over time is recorded....
The deployment and use of greenhouse sensors is a very important and critical part of my country's agricultural production at present. Due to the complex and changeable environmental conditions of the greenhouse, it is necessary to select and arrange reasonably according to different needs in th...