1.Non contact level sensor product principle
non contact level sensor uses pulse radar for liquids to accurately record levels in liquid media reliably and accurately.The radar level antenna emits narrow microwave pulses, which are transmitted downward through the antenna. After the microwave contacts the surface of the measured medium, it is reflected back and is received again by the antenna system. The signal is transmitted to the electronic circuit part and automatically converted into a level signal (because the microwave propagates extremely fast, the electromagnetic wave reaches the target and is reflected back to the receiver. The time taken is almost instantaneous).
2. Technical parameters of non contact level sensor
Product Features: PTFE cone antenna
Typical applications: liquids, powders, places with high hygiene levels, places prone to crystallization, condensation, and easy adhesion of oil fumes and dust, etc.
Measuring range: 30 meters
Antenna material: PTFE (optional)
Accuracy: ±5mm
Process temperature: -40~260℃
Process pressure: -0.1~4.0Mpa
Power supply: 24vDC (two wires, four wires)
Signal output: 4~20mA/Har (two wires/four wires)
RS485/Modbus
Process connection: flange (≥DN50 optional)
Protection level: IP67
Frequency range: 26GHz
Protection level: IP67
Explosion-proof level: ExiaⅡC T6 Ga/Exd ia IIC T6 Gb
On-site display: LED (standard configuration)
Cable entry: M20*1.5, ½NPT (optional)
Shell material: cast aluminum, 304 stainless steel (optional)
3. Non contact level sensor product features
The antenna is small in size and easy to install; the non-contact radar has no wear and pollution.
Almost unaffected by corrosion and foam; almost unaffected by water vapor, temperature and pressure changes in the atmosphere.
Serious dust environment has little impact on the operation of high-frequency level meters.
The wavelength is shorter and reflects better on tilted solid surfaces.
The beam angle is small and the energy is concentrated, which enhances the echo capability and helps avoid interference.
The measurement blind area is smaller, and good results can be achieved for small tank measurements.
High signal-to-noise ratio for better performance even under fluctuating conditions.
High frequency, it is the best choice for measuring solids and low dielectric constant media.
In the protracted battle of preventing and controlling air pollution, accurately monitoring pollution sources and grasping the dynamic change trends of pollution are important prerequisites for implementing effective governance. The Air Quality Micro-station launched by Fengtu is a key instrument in...
Ultrasonic wind speed sensor is a sensor used to measure wind speed, it adopts the ultrasonic principle and utilizes transmitting and receiving ultrasonic waves to measure wind speed. It consists of a transmitter, a receiver, a controller and a data processing unit. The transmitter transmits ultraso...
Water quality monitoring stations need to obtain real - time data of various water quality parameters, such as pH value, dissolved oxygen, chemical oxygen demand (COD), ammonia nitrogen, etc. Water quality sensors are devices specifically designed to measure these parameters. They can convert the ph...
Measurement of wind speed and direction plays a crucial role in industrial production and scientific experiments, especially in the field of wind power, and their data is of inestimable value for the operation and maintenance of wind power equipment. In recent years, with the continuous progress of...