one.ph sensor definition application environment description
ph sensor definition is one of the most important tools for measuring pH and is used to measure the acidity or alkalinity of a liquid or solution, with pH representing its acidity or alkalinity.It is used for environmental water quality testing and various high/low ionic strength water sample testing, and can meet the requirements of most industrial/environmental applications for online pH measurement.
Signal output: RS485 (MODBUS-RTU), 4-20mA current output.
Low impedance sensitive glass film, internal signal isolation technology, strong anti-interference.
Good reproducibility, thermal stability, low drift, small size, fast response
Easy and simple installation, 3/4NPT pipe thread, easy to sink in or install in pipes and tanks, stable performance, long service life
IP68 waterproof standard
two. ph sensor definition technical parameters
| Measurement principle | Electrochemistry (Salt Bridge) |
| Signal mode | RS485 (MODBUS-RTU) |
| Measuring range | 0~14.00(PH) |
| Measurement resolution | 0.01 |
| Measurement accuracy | ±0.1PH, ±0.1℃ |
| response time | About 10s (98% flowing liquid) About 15s (98% still liquid) |
| Shell material | ABS |
| temperature compensation | Automatic temperature compensation |
| Cable length | Standard 5 meters |
| Supply voltage | 12-24VDC (0.4W@12V) |
| Measurement environment | Temperature 0~50℃ (non-freezing), < 0.2MPa |
| Waterproof level | IP68 |
| Installation method | Submersible installation, NPT3/4 thread |
three. ph sensor definition installation and electrical connections
1.Installation
Note: The sensor cannot be installed upside down or horizontally, and must be installed at an angle of at least 15 degrees.
2. Electrical connection
The cable is a 5-core shielded wire, and the wire sequence is defined as:
Brown - power cord (12~24VDC) black - ground wire (GND)
Green-485B Yellow-485A
The wiring sequence should be carefully checked before powering on to avoid unnecessary losses caused by wiring errors.
Four. ph sensor definitionmaintenance and care
When used for the first time or not used again for a long time, the sensitive bulb and reference junction should be immersed in 3.3mol/L KCI solution for more than 2 hours.
Before use, it should be washed and dried with deionized water (or distilled water) to prevent impurities from being brought into the liquid being measured. 1/3 of the sensor should be inserted into the liquid being measured.
The wiring terminal part should be kept clean and dry. The sensor should be cleaned when not in use and inserted into a protective sleeve with 3.3mol/L KCI solution, or the sensor should be inserted into a container with 3.3mol/L KCI solution.
Check whether the wiring terminals are dry. If there are stains, please wipe them with absolute alcohol and dry them before continuing to use them. The sensor should avoid being immersed in deionized water, protein solution, strong acid and alkali solution, and acidic fluoride solution for a long time, and prevent contact with silicone grease. If the sensor has been used for a long time, its glass film may become translucent or have sediments attached. In this case, it can be washed with dilute hydrochloric acid and rinsed with water.
When the sensor has been used for a long time and measurement errors occur, it can be calibrated and corrected by cooperating with the instrument. If the sensor cannot be calibrated and measured after maintenance and maintenance in the above way, it means that the sensor has failed. Please replace the sensor.
Soil moisture weather stations are like doctors who conduct health checks on the soil. These doctors are equipped with various instruments that can tell us whether the soil is dry or wet, whether the temperature is high or low, whether there is enough nutrients in the soil, and what the pH level is,...
In industry, liquid level measurement of corrosive media is a critical process, and Corrosive liquid level sensors, such as the YW - 26B, are the primary application instruments. Below is a detailed explanation of the working principle and usage method of such level gauges.The YW - 26B Corrosive liq...
Duct air velocity measurement is a common operation in industrial production and environmental monitoring. Its main purpose is to monitor the flow rate of wind velocity inside a pipeline to ensure that the fluid (usually gas) inside the pipeline is within a controlled range.In industrial production,...
IV curve testing is an important means to evaluate the electrical performance of photovoltaic modules or arrays. By measuring the current of photovoltaic devices at different voltages, the current-voltage (IV) curve is plotted, and key parameters such as short-circuit current, open-circuit voltage,...