Model:FT-SS6
Brand:fengtu
1. ORP Meter Product Introduction
ORP Meter can be used to measure the ORP value of aqueous solution with high precision, which is a cost-effective portable ORP meter.SS6 model ORP Meter is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect water quality ORP parameters.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.ORP Meter host parameters
Charging input voltage | 4.5V-5.5V |
Charging current | <2A |
screen size | 3.5 inches |
screen resolution | 480*800☆ |
screen interface | MIPI DSI☆ |
USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
RS485 | 2 (Supports Modbus, json, asc input, etc.) |
External sensor supply voltage | 12V |
External sensor supply current | 1A |
operating system | ftiot (based on Linux-5.4)☆ |
CPU | 2*Cotex-A7, 650Mhz☆ |
RAM | 512M DDR3☆ |
Flash | 8G-64G |
OpenGL | ES 2.0☆ |
Wifi | support |
4G | Optional |
button | support |
capacitive touch screen | support |
software architecture | B/S☆ |
web access | Support☆ |
MTP mode | Support☆ |
Multiple terminal login | Support☆ |
IPV6 | Support☆ |
Sensor communication method | RS485, TCP, UDP, HTTP☆ |
Data forwarding method | RS485, TCP, UDP, HTTP☆ |
Remote SSH | Support☆ |
remote debugging | Support☆ |
3.ORP Meter sensor parameters and configuration
serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ✔ | |
4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | ||
5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | contact electrode method | ±1.5% | ||
6 | salinity | 0-2.5ppt or 0-80ppt | contact electrode method | ±0.05ppt or ±1ppt | ||
7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | Optional | |
0~1000NTU (medium turbidity) | scattered light method | ±1% | ||||
0~3000NTU (high turbidity) | scattered light method | ±1% | ||||
9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | ||
10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion selective electrode method | 10% of reading, ±0.5℃ | ||
11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. | |
13 | Chloride ions | 0-3500.0mg/L | Ion selective electrode method | ±5% | ||
14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | ||
15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
Fengtu Automatic Soil Monitoring System is dedicated to mitigating the effects of drought disasters by deploying soil moisture sensors and integrating web-based technologies to create a comprehensive decision-aid platform that integrates soil moisture data management, querying, and predictive analyt...
Among the many wind measuring instruments, wind cup anemometers have become more common in the history of their use because of their low cost and ease of use. But at the same time there are many problems, such as these mechanical devices due to moving parts, easy to wear and tear, the size of the ne...
The Mini Ultrasonic Anemometer has many obvious advantages in the field of wind speed and direction monitoring.First of all, for application scenarios that need to consider economy, it is an ideal choice. It can play a role in both land and marine environments. Different from traditional wind cups,...
In the fields of atmospheric and tunnel environment detection, every data point is crucial for ensuring safety and the accuracy of decision - making. The FT - FT - SGT1 portable light transmittance detector emerges as your reliable detection partner.Operationally, the FT - SGT1 detector is extremely...